Error: The default gateway '...' is identical to the network's network address.

The default gateway of the network has an invalid value because the octets set to 0 in the subnet mask must not be zero in the default gateway.

Error examples

Invalid default gateway 192.168.0.0 if subnet mask is set to 255.255.0.0.
Invalid default gateway 192.168.2.0 if subnet mask is set to 255.255.255.0.

Remedy

To fix this error, enter a valid default gateway for the network.

  1. Double-click the 'Project' node in the PLANT and open the 'Settings' editor.

    Alternative: For many errors which refer to the project IP range, double-clicking the error message directly opens the 'Settings' editor.

  2. Specify/correct the suspected 'IP range' setting(s) and confirm each entry with <Enter>.

Background: Subnet mask