S_MutingLamp input
State-controlled input for the feedback signal from the muting lamp.
Data type: SAFEBOOL
Initial value: SAFEFALSE
The signal at this input indicates whether the connected muting lamp is functioning correctly or not.
Connection: Connect this input to the feedback signal of a muting lamp connected to the Safety PLC, either directly or via other safety-related functions/function blocks. It can be connected to the SAFETRUE constant if your risk analysis for the application indicates that a muting lamp with feedback signal is not necessary.
Value | Description |
---|---|
SAFETRUE | Muting lamp is in working order (irrespective of whether the muting lamp is being controlled or not). |
SAFEFALSE | Muting lamp is non-functional. |
Single-channel or two-channel muting lamp?
Irrespective of whether the muting lamp provides a single-channel or two-channel feedback signal, the S_MutingLamp input is only connected to one signal.
If a two-channel muting lamp is used, either the input channels of the safety-related input device must be parameterized accordingly or the SF_Equivalent or SF_Antivalent function blocks must be connected upstream for evaluating or monitoring the two-channel signal (e.g., SF_Equivalent function block for equivalence monitoring).