S_AOPD_In input
State-controlled input for the status of the safety-related equipment (e.g., light grid).
Data type: SAFEBOOL
Initial value: SAFEFALSE
Connection: Connect this input to an optoelectronic safety-related equipment (e.g., a light grid) connected to the Sicherheitssteuerung, either directly or via other safety-related functions/function blocks. Constant SAFETRUE or SAFEFALSE values are not permitted.
If the function block is activated (input Activate = TRUE), the possible values at this input lead to the following function block behavior:
Value | Description | ||
---|---|---|---|
SAFEFALSE | The light beam of the optoelectronic safety-related equipment is interrupted.
|
||
SAFETRUE | The light beam of the optoelectronic safety-related equipment is not interrupted. |
Single-channel or two-channel safety-related equipment?
Irrespective of whether there is a single-channel or two-channel connection between the safety-related equipment and the Sicherheitssteuerung, the S_AOPD_In input is only connected to one signal.
If a two-channel safety-related equipment is used, either the input channels of the safety-related input device must be parameterized accordingly or the SF_Equivalent or SF_Antivalent function blocks must be connected upstream for evaluating or monitoring the two-channel signal (e.g., SF_Equivalent function block for equivalence monitoring).