S_TwoHandOut output

Control signal for stopping (stop request) or starting and maintaining machine operation

Data type: SAFEBOOL

The state of this signal depends on the states at inputs S_Button1 and S_Button2 of the function block, and whether the function block is activated and has detected an error.

Hinweis
As the enable signal is present at the S_TwoHandOut output, this output is also referred to as the enable output.

Connection: Connect the S_TwoHandOut output to an output terminal of your application, either directly or via other safety-related functions/function blocks.

The enable signal may only control the process directly if this does not adversely affect the safety-related function.

WARNUNG
Unintended machine operation
  • Verify that the enable signal only controls the process directly if this does not adversely affect the safety-related function.
  • Validate the overall safety-related function, including the start-up behavior of the process, and thoroughly test the application.

ValueDescription
SAFETRUEThe S_TwoHandOut output can only be SAFETRUE if the following conditions are met:

  • The function block has been activated (input Activate = TRUE)
  • and both inputs switch from SAFEFALSE to SAFETRUE, either simultaneously or consecutively, within a period of 500 ms (both buttons on the two-hand control device are actuated within 500 ms)
  • and the function block does not detect any errors.
SAFEFALSEThe S_TwoHandOut output is SAFEFALSE if

  • the function block is not activated (input Activate = FALSE)
  • or one or both inputs are showing the SAFEFALSE state (i.e., none or only one button actuated)
  • or both inputs are SAFETRUE, but only one input had the initial state SAFEFALSE prior to this (only one button is actuated again; the other button was not released and remained actuated throughout)
  • or the function block has detected an error (output Error = TRUE) because, for example, the maximum time offset of 500 ms for the switching operations at the inputs has been exceeded.