S_TwoHandOut output
Control signal for stopping (stop request) or starting and maintaining machine operation
Data type: SAFEBOOL
The state of this signal depends on the states at inputs S_Button1 and S_Button2 of the function block, and whether the function block is activated and has detected an error.
Hinweis
As the enable signal is present at the S_TwoHandOut output, this output is also referred to as the enable output. |
Connection: Connect the S_TwoHandOut output to an output terminal of your application, either directly or via other safety-related functions/function blocks.
The enable signal may only control the process directly if this does not adversely affect the safety-related function.
Unintended machine operation
- Verify that the enable signal only controls the process directly if this does not adversely affect the safety-related function.
- Validate the overall safety-related function, including the start-up behavior of the process, and thoroughly test the application.
|
Value | Description |
SAFETRUE | The S_TwoHandOut output can only be SAFETRUE if the following conditions are met:
- The function block has been activated (input Activate = TRUE)
-
and both inputs switch from SAFEFALSE to SAFETRUE, either simultaneously or consecutively, within a period of 500 ms (both buttons on the two-hand control device are actuated within 500 ms)
-
and the function block does not detect any errors.
|
SAFEFALSE | The S_TwoHandOut output is SAFEFALSE if
- the function block is not activated (input Activate = FALSE)
-
or one or both inputs are showing the SAFEFALSE state (i.e., none or only one button actuated)
-
or both inputs are SAFETRUE, but only one input had the initial state SAFEFALSE prior to this (only one button is actuated again; the other button was not released and remained actuated throughout)
-
or the function block has detected an error (output Error = TRUE) because, for example, the maximum time offset of 500 ms for the switching operations at the inputs has been exceeded.
|