S_OSSD_In input
State-controlled input for the status of the connected safety-related sensor. 
This input processes the status signal of the safety-related sensor (normal operation, test or request for the safety-related function). The signal present must be SAFETRUE so that the safety-related  S_OSSD_Out output can be switched to SAFETRUE.
 Data type: SAFEBOOL
Initial value: SAFEFALSE
Connection: Connect this input to the signal of a safety-related sensor (ESPE type 2) connected to the Safety PLC, either directly or via additional safety-related functions/function blocks. Constant SAFETRUE or SAFEFALSE values are not permitted.
If the function block is activated (input Activate = TRUE), the possible values at this input lead to the following function block behavior:
| Value | Description | 
|---|---|
| SAFETRUE | The light beam of the safety-related sensor is not interrupted.Refer to the warning below this table.The safety-related sensor is in normal operation, which means that no tests are active and the safety-related function has not been requested. The S_OSSD_Out output is switched to SAFETRUE provided that the function block has not detected any errors. | 
| SAFEFALSE | The safety-related sensor is either in the process of performing a test or the light beam of the safety-related sensor is interrupted. The SAFEFALSE value can also indicate that a safety-related sensor is either disabled or inoperable. | 
If no start-up inhibit is specified for the function block, the SAFETRUE status at the S_OSSD_In input can cause the S_OSSD_Out output to immediately switch to SAFETRUE.
|  WARNING | 
| Unintended start-up If no start-up inhibit is specified: 
 |