S_TwoHandOut output
Control signal for stopping (stop request) or starting and maintaining machine operation.
Data type: SAFEBOOL
The state of this signal depends on the states at inputs S_Button1 and S_Button2 of the function block, and whether the function block is activated and has detected an error.
| Note As the enable signal is present at the S_TwoHandOut output, this output is also referred to as the enable output. | 
Connection: Connect the S_TwoHandOut output to an output terminal of your application, either directly or via other safety-related functions/function blocks.
The enable signal may only control the process directly if this does not adversely affect the safety-related function.
|  WARNING | 
| Unintended machine operation 
 | 
| Value | Description | 
|---|---|
| SAFETRUE | The S_TwoHandOut output can only be SAFETRUE if the following conditions are met: 
 | 
| SAFEFALSE | The S_TwoHandOut output is SAFEFALSE if 
 |