Options - Adapting PLCnext Engineer
Select 'Extras > Options' to call the 'Options' dialog where you can adapt PLCnext Engineer and its user-interface. The dialog is separated into various categories.
| Category | Meaning | ||
|---|---|---|---|
| International | |||
| International Settings | Select the 'Language' of the user interface and then restart the application to apply the new setting. | ||
| Default Language Settings | After setting a default language and at least one alternative language, PLCnext Engineer supports the display/use of translated HMI texts and user comments.The translated strings must be provided ...
|
||
| Tool | |||
| Auto Save | Select 'Enable auto save' to activate the function and define the time interval (1 to 480 minutes).After an abnormal PLCnext Engineer termination, PLCnext Engineer checks on restart whether an auto save project is available. If existent, a message dialog appears where you can decide to load the auto save project. The folder where the auto Save project are saved is located in the same path as (i.e., parallel to) the 'Binaries' folder (see category 'Tool | Directories'). PLCnext Engineer keeps only one auto save project.
|
||
| Directories |
|
||
| Recycle Bin | By default, when you delete an element in the COMPONENTS area or the PLANT, the element is moved to the RECYCLE BIN window (located in the Cross Function Area) so that you can restore the element.The 'Disable recycle bin' checkbox is used to turn off the use of the recycle bin and delete the elements permanently instead of moving them to the RECYCLE BIN window. | ||
| Version Information | Select the description format to be used by default for the description editor (part of the 'Version Information' editor). The description editor allows you to enter your documentation for the project, POUs, and HMI symbols. The setting is applied when creating a new project.
|
||
| Text Editor | |||
| General | Editor-specific settings:
|
||
| Tabs | Allows to define the default indentation and tab size settings for the text editor.
Indentation
|
||
| Printing | |||
| Company Information | Enter the information on your company to be printed. Observe the maximum size of the logo bitmap. Refer to the topic "Print Project" for details. |
||
| Settings | The print scaling range is the minimum/maximum scaling factor with which PLCnext Engineer tries to print the entire network width onto one page. If this is not possible, the network layout is distributed on several pages as space-saving as possible.When setting the value to '1' (means 100% scaling in the editor/in Windows), one screen pixel corresponds to approximately one printer pixel. | ||
| Online | |||
| Online Values | Set the format of online values shown in online worksheets, i.e., when monitoring or debugging the application.
‣ Debug mode: Monitoring the Application Execution
×‣ WATCHES: Monitoring/Debugging the Application ×‣ Debugging Code: Forcing/Overwriting ×‣ Debugging SFC Code ×‣ Monitoring/Debugging the Safety PLC ×‣ Monitoring Mode: Displaying Online Values ×‣ Debugging Safety-Related Code: Forcing/Overwriting ×‣ WATCHES: Monitoring/Debugging the Safety-Related Application × for details. |
||
| Communication Settings | PLCnext Engineer and PLCnext Technology controllers communicate via a TCP connection with TLS Handshake.
Poor internet connection? Performance problems due to VPN connection? You can adapt the TCP communication settings by increasing the handshake timeout value and the polling interval.
|
||
| Write and Start Settings | If you are operating on a network with a slow connection or the latency on your network is high, disable the 'Use optimization' option (option is enabled by default).
: the file system on the controller is cleared, all the necessary files will be created on the controller and all of the files belonging to the project will be sent to the controller when downloading. The files are not checked for any modifications with disabled option.
: PLCnext Engineer checks the project files for changes before downloading the project to the controller. Only the changed files will be downloaded after completion of the checks. These checks are more time consuming on slow connections but faster on fast connections. Keep 'Use optimization' enabled when working in a LAN. |
||
| Write and Start Commands | The checkboxes allow you to choose which 'Write and Start' commands will appear in the cockpit toolbar under the drop-down button or the context menu of the controller node in the PLANT. By default, all checkboxes are enabled.The 'Default command' lets you specify which command appears first in the list of the 'Write and Start' drop-down button and the controller's context menu and which command is executed when clicking the drop-down button itself.If a Safety PLC is included in your project, the safety application can be written to it along with the standard application. For that purpose, the commands 'Write and Start Project (incl. Safety)' (with and without project sources) are available.For further information refer to the topics "Controller Commissioning: From Compiling to Debugging" and "Controller Cockpit - Toolbar". |
||
| Compiler | |||
| IEC Compiler Settings |
|
||
| Warnings Settings | Use this category to suppress the output of selected warning messages in the MESSAGES window. If a checkbox of a warning is activated, the warning will not be shown in the MESSAGES window and it will not be counted in the build result (number or errors and warnings) displayed in the status bar. By default, all warnings are enabled (visible in the MESSAGES window).Activate the checkboxes of the warning(s) you want to hide in the MESSAGES window.
|
||
| GSDML Import | |||
| GSDML Import Settings | Use the category to configure the endianness to be used for the conversion and representation of process data when importing Profinet devices from GSDML files.With 'Recommended Profinet Endianness' set to 'Yes' (default setting), big endian is used when importing. With 'No', little endian is used for the data conversion and representation.
|
||
| EN/ENO | |||
| EN/ENO Settings | The checkboxes allow you to choose whether functions with or without EN/ENO formal parameters will be inserted into FBD or ST code worksheets by default.With activated checkboxes, all newly inserted blocks in FBD will have EN/ENO formal parameters (EN/ENO pins). In ST, the tooltip shows two prototypes of the function (with EN/ENO and without EN/ENO) when typing the function name.See the topic "Inserting POUs with EN/ENO" for further details. | ||
| Cross references | |||
| Settings | With activated 'Collect cross references after initial project compilation' checkbox, the cross references are automatically collected in the CROSS REFERENCES Window when initially opening/compiling a project. | ||
| HMI Editor | |||
| Page Settings | Set basic worksheet properties for HMI pages. | ||
| Symbol Settings | Set basic properties for HMI symbols. | ||
| Administration | |||
| Trust Stores | Use the category to add, enable/disable, and remove device communication (controller) certificates and code signing certificates to PLCnext Engineer.
|
||
| Password Manager | PLCnext Technology controllers allow to store your credentials (user name and password) in PLCnext Engineer when logging on to the controller. (For that purpose, the checkbox 'Remember credentials' must be marked in the LOGIN mask.) The button 'Delete' removes the stored credentials from the PC and you have to enter them again when logging on the next time.Refer to the section "Storing user credentials for controller logon" for details in the storing mechanism. | ||
| Application Control Interface | Enables the use of the Application Control Interface (ACI). The ACI is an internal interface of PLCnext Engineer which allows remote access to and controlling of the engineering tool. Via the ACI, an external application can perform the same operations as via the PLCnext Engineer user interface.
|
||
| Data Integrity | Enables/disables the project integrity check (hash protection of projects and libraries locally stored on your computer) in PLCnext Engineer. With activated 'Enabled' checkbox (hash protection is activated), PLCnext Engineer calculates hash codes (numeric value of fixed length that uniquely identifies data) about the project. The project's hash codes are checked for mismatching or missing hashes when opening the project. Depending on the protection level selected here, you will be informed with a warning/error message and the appropriate action will be performed.With deactivated hash protection ('Enabled' checkbox deactivated; default setting), PLCnext Engineer does not use hash codes for comparison of project contents. No hash codes are calculated and checked. You will not be informed whether a project has or does not have hash codes.Select the 'Protection Level' you want to use:
|
||
| Physical Topology | |||
| General | General representation
Choose whether to show or hide the device labels for the device symbols and the connection labels for the device connections in the 'Physical Topology' editor.The 'Device label' drop-down list provides the following options:
Choose whether to show or hide the display of the color markings of the connections relating to an Application Relation (AR) between a Profinet controller and its Profinet devices in the 'Profinet' view in the 'Physical Topology' editor.Refer to the subchapter "Profinet ARs / color markings of participants and connections" in the chapter "Profinet" for details. |
||
| Compare | |||
| Settings | Activate the 'Include libraries for compare' checkbox to include referenced libraries in the project comparison. | ||
| Extensions | |||
| Aspect Hierarchies | If enabled, the PLANT provides additional views on the project (functional, locational and instantiated Automation Modules) which are represented as different tabs in the PLANT window. The main project view showing the usual instance tree is then contained in a separate tab. Furthermore, the COMPONENTS area provides the 'Automation Modules' category.Refer to the chapter "Automation Modules" for details. | ||
| Graphic Editor | |||
| NOLD Options | With activated checkbox, you can set the page width for new NOLD/SNOLD worksheets to a specific size using the slider, i.e., the worksheet is restricted to the right. The size is defined by the number of contacts placed in a network rung (range from 8 to 16 contacts).If the checkbox is deactivated, the size of the NOLD/SNOLD worksheet is unlimited (slider is deactivated). In this case, the worksheet content is treated and printed in the same way as in LD worksheets. When you print an unlimited network that does not fit the printer page width, the scaling factor set under the 'Printing > Settings' category is applied.
|
||
| Safety | |||
| Settings | 'Password timeout' defines the time interval after which you are automatically logged off ‣ Safety-Related Area: General Information
×‣ Safety PLC Password Protection × after a period of inactivity. Allowed value range: 10 to 60 minutes. |
||